skaliy commited on
Commit
0d7d676
1 Parent(s): 0f36041

Update README.md

Browse files
Files changed (1) hide show
  1. README.md +7 -8
README.md CHANGED
@@ -16,14 +16,14 @@ Last checked and validated with fastMONAI version 0.3.2. Please ensure that you
16
 
17
  ![Suggested pipeline](pipeline.png)
18
 
19
- ## Data Collection
20
 
21
  ### Origin of MRI Scans
22
  - **Haukeland University Hospital (HUH)**: 15 T2-weighted MRI scans
23
  - **Sahlgren-ska University Hospital (SUH)**: 10 T2-weighted MRI scans
24
 
25
- ### HUH Data
26
- - **Study**: [AIM-study (Antibiotics In Modic changes)](https://trialsjournal.biomedcentral.com/articles/10.1186/s13063-017-2306-8)
27
  #### Scanner Specifications
28
  - Type: Siemens MAGNETOM Avanto 1.5 T
29
  - Slice Thickness: 4 mm
@@ -34,8 +34,8 @@ Last checked and validated with fastMONAI version 0.3.2. Please ensure that you
34
  - Echo Time: 87 ms
35
  - Number of Acquisitions: 2
36
 
37
- ### SUH Data
38
- - [Link to Sahlgrenska Data](https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5789539/)
39
  #### Scanner Specifications
40
  - Type: Siemens MAGNETOM Aera 1.5 T
41
  - Slice Thickness: 3.5 mm
@@ -46,14 +46,13 @@ Last checked and validated with fastMONAI version 0.3.2. Please ensure that you
46
  - Echo Time: 95 ms
47
  - Number of Acquisitions: 1
48
 
49
- ## Data Annotation
50
-
51
  - **Process**: Manual segmentation of vertebrae
52
  - **Experts**: Conducted by an MRI expert with consensus from a senior radiologist
53
  - **Software**: ITK-SNAP
54
  - **Scope**: Segmented vertebrae in all slices, including bone marrow but excluding vertebral cortex
55
 
56
- ## External Data Evaluation
57
 
58
  - **Source**: [Annotated T2-weighted MR images of the Lower Spine](https://zenodo.org/record/22304)
59
  - **Scan Specifications**: 23 scans, 1.5 T in sagittal orientation
 
16
 
17
  ![Suggested pipeline](pipeline.png)
18
 
19
+ ## Data
20
 
21
  ### Origin of MRI Scans
22
  - **Haukeland University Hospital (HUH)**: 15 T2-weighted MRI scans
23
  - **Sahlgren-ska University Hospital (SUH)**: 10 T2-weighted MRI scans
24
 
25
+ ### Haukeland University Hospital (HUH): 15 T2-weighted MRI scans
26
+ - [Study](https://trialsjournal.biomedcentral.com/articles/10.1186/s13063-017-2306-8)
27
  #### Scanner Specifications
28
  - Type: Siemens MAGNETOM Avanto 1.5 T
29
  - Slice Thickness: 4 mm
 
34
  - Echo Time: 87 ms
35
  - Number of Acquisitions: 2
36
 
37
+ ### Sahlgren-ska University Hospital (SUH): 10 T2-weighted MRI scans
38
+ - [Study](https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5789539/)
39
  #### Scanner Specifications
40
  - Type: Siemens MAGNETOM Aera 1.5 T
41
  - Slice Thickness: 3.5 mm
 
46
  - Echo Time: 95 ms
47
  - Number of Acquisitions: 1
48
 
49
+ ### Data Annotation
 
50
  - **Process**: Manual segmentation of vertebrae
51
  - **Experts**: Conducted by an MRI expert with consensus from a senior radiologist
52
  - **Software**: ITK-SNAP
53
  - **Scope**: Segmented vertebrae in all slices, including bone marrow but excluding vertebral cortex
54
 
55
+ ### External Data Evaluation
56
 
57
  - **Source**: [Annotated T2-weighted MR images of the Lower Spine](https://zenodo.org/record/22304)
58
  - **Scan Specifications**: 23 scans, 1.5 T in sagittal orientation